The physics is simple, but the economics are where it getsinteresting. Under -95 kPa vacuum, water boils at 40°C instead of 100°C. That60-degree gap doesn't just change the boiling point — it fundamentally rewritesthe energy equation. Here's why, with real numbers from operating VIFLUTERsystems.

The Clausius-Clapeyron Reality
At atmospheric pressure (101.3 kPa), water needs 2,257 kJ tovaporize one kilogram — the latent heat of vaporization. At 40°C under vacuum,it needs roughly 2,407 kJ/kg. Slightly more per kilogram, yes. But you don'thave to pay for the 60 degrees of sensible heating from 40°C to 100°C, whichcosts an additional 252 kJ/kg.
More importantly, you can now use a heat pump instead of a boiler.A boiler burns fuel to generate steam at roughly 85% efficiency. A heat pumpmoves existing heat with a coefficient of performance (COP) of 8-10 inVIFLUTER's FC series. That means 1 kWh of electricity moves 8-10 kWh of thermalenergy. A fossil-fueled boiler delivers less than 1 kWh of usable heat per kWhof fuel burned.
Energy per Ton: The Number That Matters
Operators care about one metric: kilowatt-hours per ton of waterevaporated. Atmospheric single-effect steam evaporation costs 650-700 kWh perton in practice. A vacuum heat pump evaporator like VIFLUTER's FC seriesdelivers 150-250 kWh per ton — roughly one-third to one-quarter the energy. Fora plant evaporating 10 tons of wastewater per day, that's a difference ofroughly 5,000 kWh daily, or 1.5 million kWh annually.
Why 40°C Matters Beyond Energy
The low temperature isn't just about the electricity bill. Calciumcarbonate scaling — the most common fouling mechanism in industrial evaporators— accelerates dramatically above 60°C. By operating below that threshold, thescaling rate drops significantly. VIFLUTER systems on high-hardness coal miningwastewater run 3-4 weeks between CIP (clean-in-place) cycles, versus 5-7 dayson a comparable steam evaporator.
There's another benefit that chemical plants care about.Heat-sensitive materials — enzyme proteins, plant extracts, pharmaceuticalintermediates — degrade above 50°C. Vacuum evaporation at 40°C preservesproduct integrity. A muscone manufacturer using VIFLUTER equipment reported a5-10% yield increase over their previous 70-80°C steam evaporator, alongside a60% energy cost reduction.
The Real-World COP Story
COP on a spec sheet and COP in the field are different numbers.VIFLUTER's oil-free scroll compressors achieve a design COP of 9-10 on cleanwater. On real wastewater — with TDS climbing from 5,000 to 150,000 mg/L duringa batch cycle — the effective COP drops slightly as boiling point elevationincreases the temperature lift the compressor must provide.
That's why forced circulation matters: maintaining tube-sidevelocity keeps the heat transfer coefficient high even as the concentratethickens. A falling film design on the same duty would see its COP collapse asthe film distribution degrades with viscosity.
Bottom Line
Vacuum evaporation doesn't eliminate the energy cost of boilingwater — that's a fundamental thermodynamic requirement. What it eliminates isthe sensible heating penalty, the boiler infrastructure, and the scalingacceleration that kills evaporator performance. The result is 70-80% lessenergy per ton of water treated, in exchange for running a vacuum pump and acompressor. The math works.
Run your water chemistry through VIFLUTER's energy model. We'llgive you real COP and kWh-per-ton projections based on your actual feed — not abrochure number.